Clean your Toilets & Bathrooms with Clenzer Power - Standard Operating Procedure (SOP)

Posted by Clenzer Care on

Follow the guidelines below for applying Clenzer Power when used for Toilet & Bathroom Cleaning.  Add 10 ml (½ cap) of Clenzer in 990 ml of water (dilution 1 : 99) to prepare 1 litre of the disinfectant solutionNote : Ensure the ratio 1:99 to prepare alternate quantities of the disinfectant solution. Use room temperature or cold water and not hot water. Apply the solution on the surface and leave it for around 5 minutes.Note : Use a soft absorbent cloth or mop (preferably a microfiber cloth over a cotton cloth) to apply the solution. Agitate the surface with suitable scourer, brush...

Read more →

Clean your Door Handles & Knobs with Clenzer Power - Standard Operating Procedure (SOP)

Posted by Clenzer Care on

Follow the guidelines below for applying Clenzer Power when used for Door Handles, & Knobs Cleaning. Add 10 ml (½ cap) of Clenzer in 3990 ml of water (dilution 1 : 399) to prepare 4 litres of the disinfectant solution.Note : Ensure the ratio 1:399 to prepare alternate quantities of the disinfectant solution. Use room temperature or cold water and not hot water. Apply the solution on the surface and leave it for around 5 minutes.Note : Use a soft absorbent cloth (preferably a microfiber cloth over a cotton cloth) to apply the solution. Scrub the surface gently.Note : Use a...

Read more →

Remove Hard Stains with Clenzer Power - Standard Operating Procedure (SOP)

Posted by Clenzer Care on

Follow the guidelines below for applying Clenzer Power when used for Hard Stain Removal. Add 20 ml (1 cap) of Clenzer in 980 ml of water (dilution 1 : 49) to prepare 1 litre of the disinfectant solution.Note : Ensure the ratio 1:49 to prepare alternate quantities of the disinfectant solution. Use room temperature or cold water and not hot water. Apply the solution on the surface and leave it for around 5 minutes.Note : Use a soft absorbent cloth or mop (preferably a microfiber cloth over a cotton cloth) to apply the solution. Agitate the surface with suitable scourer, brush...

Read more →

Clean your Overhead Tanks & Sumps with Clenzer Power - Standard Operating Procedure (SOP)

Posted by Clenzer Care on

Follow the guidelines below for applying Clenzer Power when used for Overhead Tanks & Sumps Cleaning. Add 10 ml (½ cap) of Clenzer in 3990 ml of water (dilution 1 : 399) to prepare 4 litres of the disinfectant solution.Note : Ensure the ratio 1:399 to prepare alternate quantities of the disinfectant solution. Use room temperature or cold water and not hot water. Apply the solution on the surface and leave it for around 5 minutes.Note : Use a soft absorbent cloth (preferably a microfiber cloth over a cotton cloth) to apply the solution. Scrub the surface gently.Note : Use a...

Read more →

Clean your Pantry with Clenzer Power - Standard Operating Procedure (SOP)

Posted by Clenzer Care on

Follow the guidelines below for applying Clenzer Power when used for Pantry Cleaning. Add 10 ml (½ cap) of Clenzer in 990 ml of water (dilution 1 : 99) to prepare 1 litre of the disinfectant solution.Note : Ensure the ratio 1:99 to prepare alternate quantities of the disinfectant solution. Use room temperature or cold water and not hot water. Apply the solution on the surface and leave it for around 5 minutes.Note : Use a soft absorbent cloth (preferably a microfiber cloth over a cotton cloth) to apply the solution. Scrub the surface gently.Note : Use a soft absorbent cloth...

Read more →